This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section R106.
AAMA
American Architectural Manufacturers Association
 
 
1827 Walden Office Square
 
 
 
Suite 550
 
 
 
Schaumburg, IL 60173-4268
 
 
Standard reference number
Title
 
Referenced in code section number
AAMA/WDMA/CSA
101/I.S.2/A C440-11
North American Fenestration
Standard/Specifications for Windows, Doors and Unit Skylights
. . . . . . . .
R402.4.3
ACCA
Air Conditioning Contractors of America
 
 
2800 Shirlington Road, Suite 300
 
 
 
Arlington, VA 22206
 
 
Standard reference number
Title
 
Referenced in code section number
Manual J-11
Residential Load Calculation Eighth Edition
. . . . . . . .
R403.7
Manual S-10
Residential Equipment
. . . . . . . .
R403.7
ASHRAE
American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
 
 
1791 Tullie Circle, N.E.
 
 
 
Atlanta, GA 30329-2305
 
 
Standard reference number
Title
 
Referenced in code section number
ASHRAE-2009
ASHRAE Handbook of Fundamentals
 
R402.1.4, Table R405.5.2(1)
ASHRAE 193-2010
Method of Test for Determining the Airtightness of HVAC Equipment
. . . . . . . .
R403.3.2.1
ASTM
ASTM International
 
 
 
100 Barr Harbor Drive
 
 
 
West Conshohocken, PA 19428-2859
 
 
Standard reference number
Title
 
Referenced in code section number
C1363-11
Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus
. . . . . . . .
R303.1.4.1
E 283-04
Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen
. . . . . . . .
R402.4.5
CSA
Canadian Standards Association
 
 
5060 Spectrum Way
 
 
 
Mississauga, Ontario, Canada L4W 5N6
 
 
Standard reference number
Title
 
Referenced in code section number
AAMA/WDMA/CSA
101/I.S.2/A440-11
North American Fenestration
Standard/Specification for Windows, Doors and Unit Skylights
. . . . . . . .
R402.4.3
CSA 55.1-2012
Test Method for Measuring Efficiency and Pressure Loss of Drain Water Heat Recovery Systems
. . . . . . . .
R403.5.4, Table R406.2
CSA 55.2-2012
Drain Water Heat Recovery Units
. . . . . . . .
R403.5.4
ICC
International Code Council, Inc.
 
 
500 New Jersey Avenue, N.W.
 
 
 
6th Floor
 
 
 
Washington, DC 20001
 
 
Standard reference number
Title
 
Referenced in code section number
IBC-15
International Building Code
. . . . . . . .
R201.3, R303.2, R402.11, R4501.4
ICC 400-15
Standard on the Design and Construction of Log Structures
. . . . . . . .
Table R402.5.1.1
IFC-15
International Fire Code
. . . . . . . .
R201.3, R501.4
IFGC-15
International Fuel Gas Code
. . . . . . . .
R201.3, R501.4
IMC-15
International Mechanical Code
. . . . . . . .
R201.3, R403.3.2, R403.6, R501.4
IPMC-15
International Property Maintenance Code
. . . . . . . .
R501.4
IRC-15
International Residential Code
. . . . . . . .
R104.2.1, R201.3, R303.2, R401.2, R403.2.2, R403.5, R406.1, R406.2, Table R406.2
IEEE
The Institute of Electrical and Electronic Engineers, Inc.
 
 
3 Park Avenue
 
 
 
New York, NY 10016-5997
 
 
Standard reference number
Title
 
Referenced in code section number
515.1-2012
IEEE Standard for the Testing, Design, Installation and Maintenance of Electrical Resistance Trace Heating for Commercial Applications
. . . . . . . .
R403.5.1.2
NEEA
Northwest Energy Efficiency Alliance
 
 
421 S.W. 6th Ave., Suite 600
 
 
 
Portland, OR 97204
 
 
Standard reference number
Title
 
Referenced in code section number
NEEA-2011
Northern Climate Specification for Heat Pump Water Heaters, Vers. 4.0
. . . . . . . .
Table R406.2
NFRC
National Fenestration Rating Council, Inc.
 
 
6305 Ivy Lane, Suite 140
 
 
 
Greenbelt, MD 20770
 
 
Standard reference number
Title
 
Referenced in code section number
100-2010
Procedure for Determining Fenestration Products U-factors
. . . . . . . .
R303.1.3
200-2010
Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence
. . . . . . . .
R303.1.3
400-2010
Procedure for Determining Fenestration Product Air Leakage
. . . . . . . .
R402.4.3
UL
Underwriters Laboratory
 
 
333 Pfingsten Road
 
 
 
Northbrook, IL 60062
 
 
Standard reference number
Title
 
Referenced in code section number
UL 127-11
Factory Built Fireplace
. . . . . . . .
R402.4.2
UL 515-11
Electric Resistance Heat Tracing for Commercial and Industrial Applications
. . . . . . . .
R403.5.1.2
UL 907-94
Fireplace Accessories (with revisions through April 2010)
. . . . . . . .
R402.4.2
US-FTC
United States-Federal Trade Commission
 
 
600 Pennsylvania Avenue N.W.
 
 
 
Washington, DC 20580
 
 
Standard reference number
Title
 
Referenced in code section number
C.F.R. Title 16
(May 31, 2005)
R-value
. . . . . . . .
Rule R303.1.4
WDMA
Window and Door Manufacturers Association
 
 
1400 East Touhy Avenue, Suite 470
 
 
 
Des Plaines, IL 60018
 
 
Standard reference number
Title
 
Referenced in code section number
AAMA/WDMA/CSA
101/I.S.2/A440-11
North American Fenestration
Standard/Specification for Windows, Doors and Unit Skylights
. . . . . . . .
R402.4.3
WSU
Washington State University Energy Extension Program
 
 
905 Plum Street S.E., Bldg 3
 
 
 
P.O. Box 43165
 
 
 
Olympia, WA 98506-3166
 
 
Standard reference number
Title
 
Referenced in code section number
WSU RS 33
Duct Testing Standard for New and Existing Construction Publication No. WSUEEP15-016
. . . . . . . .
R403.3.3