HTML has links - PDF has Authentication
51-11C-402141  <<  51-11C-402142 >>   51-11C-40215

PDFWAC 51-11C-402142

Table C402.1.4.2Effective R-values for steel stud wall assemblies.

Table C402.1.4.2
Effective R-values For Steel Stud Wall Assemblies
NOMINAL STUD DEPTH (inches)
SPACING OF FRAMING (inches)
CAVITYR-VALUE
(insulation)
CORRECTION FACTOR (Fc)
EFFECTIVE
R-VALUE (ER)
(Cavity R-Value × Fc)
 
3 1/2
16
13
0.46
5.98
 
15
0.43
6.45
 
3 1/2
24
13
0.55
7.15
 
15
0.52
7.80
 
6
16
19
0.37
7.03
 
21
0.35
7.35
 
6
24
19
0.45
8.55
 
21
0.43
9.03
 
8
16
25
0.31
7.75
 
24
25
0.38
9.50
[Statutory Authority: RCW 19.27A.020, 19.27A.025, 19.27A.160 and chapters 19.27A and 19.27 RCW. WSR 22-14-091, 23-12-101, and 23-20-021, § 51-11C-402142, filed 7/1/22, 6/7/23, and 9/25/23, effective 3/15/24. Statutory Authority: RCW 19.27A.025, 19.27A.160, and 19.27.074. WSR 16-03-072, § 51-11C-402142, filed 1/19/16, effective 7/1/16.]