PDFWAC 51-11R-30312
Table R303.1.3(2)—Default opaque door U-factors.
TABLE R303.1.3(2)
DEFAULT OPAQUE DOOR U-FACTORS
Door Type | No Glazed Fenestration | Single Glazing | Double Glazing with 1/4 in. Airspace | Double Glazing with 1/2 in. Airspace | Double Glazing with e = 0.10, 1/2 in. Argon | |
SWINGING DOORS (Rough opening - 38 in. x 82 in.) | ||||||
Slab Doors | ||||||
Wood slab in wood framea | 0.46 | |||||
6% glazed fenestration (22 in. x 8 in. lite) | - | 0.48 | 0.47 | 0.46 | 0.44 | |
25% glazed fenestration (22 in. x 36 in. lite) | - | 0.58 | 0.48 | 0.46 | 0.42 | |
45% glazed fenestration (22 in. x 64 in. lite) | - | 0.69 | 0.49 | 0.46 | 0.39 | |
More than 50% glazed fenestration | Use Table R303.1.3(1) | |||||
Insulated steel slab with wood edge in wood framea | 0.16 | |||||
6% glazed fenestration (22 in. x 8 in. lite) | - | 0.21 | 0.20 | 0.19 | 0.18 | |
25% glazed fenestration (22 in. x 36 in. lite) | - | 0.39 | 0.28 | 0.26 | 0.23 | |
45% glazed fenestration (22 in. x 64 in. lite) | - | 0.58 | 0.38 | 0.35 | 0.26 | |
More than 50% glazed fenestration | Use Table R303.1.3(1) | |||||
Foam insulated steel slab with metal edge in steel frameb | 0.37 | |||||
6% glazed fenestration (22 in. x 8 in. lite) | - | 0.44 | 0.42 | 0.41 | 0.39 | |
25% glazed fenestration (22 in. x 36 in. lite) | - | 0.55 | 0.50 | 0.48 | 0.44 | |
45% glazed fenestration (22 in. x 64 in. lite) | - | 0.71 | 0.59 | 0.56 | 0.48 | |
More than 50% glazed fenestration | Use Table R303.1.3(1) | |||||
Cardboard honeycomb slab with metal edge in steel frameb | 0.61 | |||||
Style and Rail Doors | ||||||
Sliding glass doors/French doors | Use Table R303.1.3(1) | |||||
Site-Assembled Style and Rail Doors | ||||||
Aluminum in aluminum frame | - | 1.32 | 0.99 | 0.93 | 0.79 | |
Aluminum in aluminum frame with thermal break | - | 1.13 | 0.80 | 0.74 | 0.63 |
Note: | Appendix A Tables A107.1(2) through A107.1(4) of chapter 51-11C WAC may also be used if applicable. | |
a | Thermally broken sill (add 0.03 for nonthermally broken sill). | |
b | Nonthermally broken sill. |
[Statutory Authority: RCW 19.27A.020, 19.27A.045, 19.27A.160, and chapter 19.27A RCW. WSR 24-03-084, § 51-11R-30312, filed 1/16/24, effective 3/15/24. Statutory Authority: RCW 19.27A.020, 19.27A.045, 19.27A.160 and chapter 19.27 RCW. WSR 20-01-047, § 51-11R-30312, filed 12/9/19, effective 7/1/20. Statutory Authority: RCW 19.27A.025, 19.27A.045, 19.27.020, and 19.27.074. WSR 14-24-123, § 51-11R-30312, filed 12/3/14, effective 1/3/15. Statutory Authority: RCW 19.27A.020, 19.27A.045 and chapters 19.27 and 34.05 RCW. WSR 13-04-055, § 51-11R-30312, filed 2/1/13, effective 7/1/13.]