PDFWAC 246-215-04206
Cleanability—CIP equipment (FDA Food Code 4-202.12).
(1) CIP equipment must meet the characteristics specified under WAC 246-215-04204 and must be designed and constructed so that:
(a) Cleaning and sanitizing solutions circulate throughout a fixed system and contact all interior food-contact surfaces; and
(b) The system is self-draining or capable of being completely drained of cleaning and sanitizing solutions; and
(2) CIP equipment that is not designed to be disassembled for cleaning must be designed with inspection access points to ensure that all interior food-contact surfaces throughout the fixed system are being effectively cleaned.