HTML has links - PDF has Authentication
296-826-30020  <<  296-826-30025 >>   296-826-30030

PDFWAC 296-826-30025

Systems mounted on trucks, semi-trailers, and trailers.

(1) You must construct and test containers, when transported within the state of Washington, according to both of the following:
(a) A minimum design pressure of 250 psig;
(b) The Unfired Pressure Vessel Code.
(2) You must construct containers used for interstate transport according to DOT regulations.
(3) You must make sure the shell or head thickness of any container is at least 3/16 of an inch.
(4) You must make sure electrical lighting circuits meet all of the following:
(a) Have suitable over-current protection, such as fuses or automatic circuit breakers.
(b) Are suitably secured, insulated, and protected against physical damage.
(c) Have wiring with sufficient carrying capacity and mechanical strength.
(5) You must use only electric light.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050. WSR 15-23-086, § 296-826-30025, filed 11/17/15, effective 12/18/15. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 06-10-067, § 296-826-30025, filed 5/2/06, effective 9/1/06.]
Site Contents
Selected content listed in alphabetical order under each group