PDFWAC 296-52-69120
Table H-23—Quantity and distance tables for manufacturing buildings.
Explosives manufacturing plants that have buildings and magazines, where workers are regularly employed, must meet the quantity and separation distance requirements of Table H-23, intraexplosives plant quantity and distance table.
(1) Explosives manufacturing buildings. Explosives manufacturing buildings must be located away from manufacturing and nonmanufacturing buildings as required by Table H-23.
(2) Magazines. Magazines must be located away from manufacturing and nonmanufacturing buildings as required by Table H-23.
Table H-23
explosives | Distance Feet | ||||
Pounds Over | Pounds Not Over | Separate Building or Within Substantial Dividing Walls | |||
. . . . | 10 | ||||
10 | 25 | 40 | |||
25 | 50 | 60 | |||
50 | 100 | 80 | |||
100 | 200 | 100 | |||
200 | 300 | 120 | |||
300 | 400 | 130 | |||
400 | 500 | 140 | |||
500 | 750 | 160 | |||
750 | 1,000 | 180 | |||
1,000 | 1,500 | 210 | |||
1,500 | 2,000 | 230 | |||
2,000 | 3,000 | 260 | |||
3,000 | 4,000 | 280 | |||
4,000 | 5,000 | 300 | |||
5,000 | 6,000 | 320 | |||
6,000 | 7,000 | 340 | |||
7,000 | 8,000 | 360 | |||
8,000 | 9,000 | 380 | |||
9,000 | 10,000 | 400 | |||
10,000 | 12,500 | 420 | |||
12,500 | 15,000 | 450 | |||
15,000 | 17,500 | 470 | |||
17,500 | 20,000 | 490 | |||
20,000 | 25,000 | 530 | |||
25,000 | 30,000 | 560 | |||
30,000 | 35,000 | 590 | |||
35,000 | 40,000 | 620 | |||
40,000 | 45,000 | 640 | |||
45,000 | 50,000 | 660 | |||
50,000 | 55,000 | 680 | |||
55,000 | 60,000 | 700 | |||
60,000 | 65,000 | 720 | |||
65,000 | 70,000 | 740 | |||
70,000 | 75,000 | 770 | |||
75,000 | 80,000 | 780 | |||
80,000 | 85,000 | 790 | |||
85,000 | 90,000 | 800 | |||
90,000 | 95,000 | 820 | |||
95,000 | 100,000 | 830 | |||
100,000 | 125,000 | 900 | |||
125,000 | 150,000 | 950 | |||
150,000 | 175,000 | 1,000 | |||
175,000 | 200,000 | 1,050 | |||
200,000 | 225,000 | 1,100 | |||
225,000 | 250,000 | 1,150 | |||
250,000 | 275,000 | 1,200 | |||
275,000 | 300,000 | 1,250 |
[Statutory Authority: RCW 49.17.010, [49.17].040, and [49.17].050. WSR 02-03-125, § 296-52-69120, filed 1/23/02, effective 3/1/02.]