PDFWAC 246-236-037

Power failures.

(1) If electrical power at a panoramic or beam-type irradiator is lost for longer than ten seconds, the sources must automatically return to the shielded position.
(2) The lock on the door of the radiation room of a panoramic or beam-type irradiator may not be deactivated by a power failure.
(3) During a power failure, the area of any irradiator where sources are located may be entered only when using an operable and calibrated radiation survey meter.
[Statutory Authority: RCW 70.98.050, 70.98.110 and 58 F.R. 7728, 76 F.R. 56963, 77 F.R. 39906, 80 F.R. 54234. WSR 18-15-017, ยง 246-236-037, filed 7/9/18, effective 8/9/18.]