Section C406.8Envelope option.

C406.8 Enhanced envelope performance. The Proposed Total Envelope UA of the building thermal envelope shall be 15 percent lower than the Allowed Total Envelope UA for a building of identical configuration and fenestration area in accordance with Section C402.1.5 and Equation 4-2.
[Statutory Authority: RCW 19.27A.020, 19.27A.025 and chapters 19.27A and 19.27 RCW. WSR 19-02-089, § 51-11C-40608, filed 1/2/19, effective 7/1/19. Statutory Authority: RCW 19.27A.025, 19.27A.045, 19.27A.160, and 19.27.074. WSR 16-13-089, § 51-11C-40608, filed 6/15/16, effective 7/16/16. Statutory Authority: RCW 19.27A.025, 19.27A.160, and 19.27.074. WSR 16-03-072, § 51-11C-40608, filed 1/19/16, effective 7/1/16.]