HTML has links - PDF has Authentication
296-807-17015  <<  296-807-17020 >>   296-807-180

PDFWAC 296-807-17020

Visually inspect jacks and keep them in good working order.

Note:
There are two types of inspection, frequent or periodic, depending on how often they are done.
(1) You must inspect jacks at appropriate intervals:
(a) Make sure frequent inspections are done by the operator or other designated person as follows:
(i) Before a jack is first placed in service;
(ii) Monthly for a jack used in normal service;
(iii) Daily or before each use for a jack used for other than normal service;
(iv) Before using a jack that has been altered, modified, or repaired;
(v) Before using a jack that has not been used in one year or more.
(b) Make sure a periodic inspection of the jack is done once a year.
(c) Inspect the jack using Table 4, Jack Inspection Requirements, during any frequent or periodic inspection.
(2) You must make sure a jack that is out of order is:
(a) Tagged;
(b) Not used until repaired.
(3) You must make sure a jack is properly lubricated at regular intervals.
Note:
The jack should be lubricated following the manufacturer's instructions.
Table 4
Jack Inspection Requirements
Inspection Item
Frequent
Inspection
Periodic
Inspection
Check all of the following items that apply to the jack:
 
Improper pawl engagement
X
X
 
Excessive pawl wear
X
X
 
Chipped, cracked, or worn rack teeth
X
X
 
Cracked or damaged housing
X
X
 
Damaged, bent, or worn threads
X
X
 
Leaking hydraulic fluid
X
X
 
Scored or damaged plunger
X
X
 
Improper functioning
X
X
 
Free movement of swivel, heads, and caps
X
X
 
Loose bolts or rivets
X
X
 
Damaged or improperly assembled accessory equipment
X
X
 
Rack wear or bending
X
X
 
Other items as specified in the manufacturer's instructions
X
X
Watch the jack during operation
X
X
More detailed inspection required if a designated person determines any condition discovered is a hazard
X
 
Clean and check internal parts for wear or damage if inspection indicates an internal problem
 
X
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050. WSR 15-23-086, § 296-807-17020, filed 11/17/15, effective 12/18/15. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 07-03-163, § 296-807-17020, filed 1/24/07, effective 4/1/07; WSR 03-09-009, § 296-807-17020, filed 4/4/03, effective 8/1/03.]