HTML has links - PDF has Authentication
16-202-1020  <<  16-202-1021 >>   16-202-1022

PDFWAC 16-202-1021

What alternative methods can be used as a system interlock?

Alternative technology used as a system interlock must fulfill the provisions of this chapter.
(1) A person may not serve as a human interlock.
(2) Solenoid and check valve.
(a) The chemical injection line must contain either a normally closed solenoid-operated valve connected to the system interlock or a normally closed hydraulically operated valve that opens only when the main water line is adequately pressurized. A normally closed, solenoid-operated valve must be placed on the intake side of the injection pump, immediately adjacent to the application tank.
(b) The chemical injection line between the application tank and the metering device must contain an automatic, quick-closing check valve to prevent the flow of liquid back toward the application tank. The check valve must be placed immediately adjacent to the venturi chemical inlet.
[Statutory Authority: Chapters 15.54, 15.58, 17.21, and 34.05 RCW. WSR 01-23-018, ยง 16-202-1021, filed 11/9/01, effective 11/9/01.]
Site Contents
Selected content listed in alphabetical order under each group